Installing an Internal Modem (Non Plug-n-Play) 25
Shutting Down to DOS
You can shut down Windows 95/98 and start DOS to run DOS
applications.
1. From the Start icon, choose Shutdown. Select Restart
Computer in MS-DOS Mode.
2. After restarting, get the A prompt (or B if you are using the B
drive.) Insert the Driver and Utilities diskette or CD and type
INSTALL. This loads the SETCOM16 program.
3. The SETCOM16 EXE program will suggest an address for the
modem. Use the tab to select OK or select Manual to change the
address.
4. SETCOM16 EXE will ask if you want to update the Windows
SYSTEM.INI file. Use the tab key to select None.
Note: Because you are running Windows 95/98, you only want to
update the AUTOEXEC.BAT file. Selecting None will do this
automatically.
5. When you return to DOS, type C:\AUTOEXEC.BAT. Scroll
through the text for a line that looks like the following example:
C:\SETCOMM\SETCOM16.EXE 3E8 5.
6. Copy the line, including the I/O address and IRQ after the .EXE.
7. Type Win at the C:\ prompt to return to Windows 95/98.
8. From the Start icon, select Programs, then Accessories.
Choose Notepad.