EasyManua.ls Logo

Heatmiser Slimline-E V3 - Advanced Thermostat Settings; Optional Features Explained

Heatmiser Slimline-E V3
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Optional Features Explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED
Feature 01 – Temperature Format: This function allows you to select between °C and °F.
Feature 02 – Switching Dierential: This function allows you to increase the switching
dierential of the thermostat. The default is 1°C which means that with a set temperature
of 20°C, the thermostat will switch the heating on at 19°C and o at 20°C.
With a 2°C dierential, the heating will switch on at 18°C and o at 20°C.
Feature 03 – Frost Protect: You can set whether the thermostat will maintain the frost
temperature when the thermostat display is turned o. As a default, this is enabled
Feature 04 – Output Delay: To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit: This function allows you to limit the use of the
up and down keys. This limit is also applicable when the thermostat is locked and so allows
you to give others limited control over the heating system.
Feature 06 – Sensor Selection: On this thermostat, you can select which sensor should
be used. You can select between air temperature only, oor temperature, or both. When
you enable both sensors, the oor sensor is used as a oor limiting sensor and is designed
to prevent the oor from overheating.
Note: Built in air sensor only MUST NOT be used to control electric underoor heating. Floor sensor
only or built in air & oor sensor together must be used.
21
Slimline Series

Related product manuals