23/31
• Before the motor is installed, the rubber-metal bearing must be checked for possible
wear or cracks and must be replaced if necessary.
• Exchange the motor.
10.3 Power board A1
• Unplug all plugs and cables from the power board.
• Remove the five fastening screws of the power board A1.
• Exchange the power board A1.
10.4 Control panel (A3)
• Remove the three fastening screws and lift up the control panel carefully.
• Unplug the flat ribbon cable from the power board A1.
• Exchange the control panel.
10.5 Flat ribbon cable
• Unplug the flat ribbon cable from the power board A1.
• Unplug the flat ribbon cable from the control board A3.
• Exchange the flat ribbon cable.
10.6 Appliance plug with mains switch
• Strip the appliance plug from the lower housing.
• Remove the plugs and the earth connection.
• Exchange the appliance plug.
10.7 Imbalance switch S2 (only with EBA 20 C)
• Pull off plug ST6 from the power board A1.
• Remove the fastening screws of the imbalance switch S2 from the sheet metal
holder.
• Exchange the imbalance switch.
• Adjust the imbalance switch, see section "Imbalance switch-off (only with
EBA 20 C)".
10.8 Lid lock Y1
• Remove the two fastening screws of the lid lock on the upper part of the housing.
• Unplug the cable from the microswitch and the solenoid of the lid lock.
• Pull off the earth connection from the lid lock.
• Exchange the lid lock.