Before the motor is installed, the rubber-metal bearing must be checked for possible
wear or cracks and must be replaced if necessary.
Exchange the motor.
10.3 Power board A1
Unplug all plugs and cables from the power board.
Remove the five fastening screws of the power board A1.
Exchange the power board A1.
10.4 Control panel (A3)
Remove the three fastening screws and lift up the control panel carefully.
Unplug the flat ribbon cable from the power board A1.
Exchange the control panel.
10.5 Flat ribbon cable
Unplug the flat ribbon cable from the power board A1.
Unplug the flat ribbon cable from the control board A3.
Exchange the flat ribbon cable.
10.6 Appliance plug with mains switch
Strip the appliance plug from the lower housing.
Remove the plugs and the earth connection.
Exchange the appliance plug.
10.7 Imbalance switch S2 (only with EBA 20 C)
Pull off plug ST6 from the power board A1.
Remove the fastening screws of the imbalance switch S2 from the sheet metal
holder.
Exchange the imbalance switch.
Adjust the imbalance switch, see section "Imbalance switch-off (only with
EBA 20 C)".
10.8 Lid lock Y1
Remove the two fastening screws of the lid lock on the upper part of the housing.
Unplug the cable from the microswitch and the solenoid of the lid lock.
Pull off the earth connection from the lid lock.
Exchange the lid lock.