IM-560en
Vers. 05
Page 30
ASSEMBLY INSTRUCTIONS
VERTICAL LIFTING PLATFORM PH-300
1 Plug the hinge post bundle into the lower part of the hinge post in case of an
automatic door.
Hinge post
cable
2 Insert the hinge post xing plate into the 3 short studs.
3 Fix the hinge post to the xation plate using three M6 nuts and orient the slot
for the cables towards the platform and leaving it slightly sloping to counteract
the exion of the tube due to the weight of the door. In order to do so, use the
adjustment bolts threaded on the base of the hinged post and then tighten the
xation nuts.
Slot for cables
Locking nut
Adjustment bolt
4 Insert the locking post xing plate and secure it with 3 M6 nuts.
Montaje de la puerta