EasyManua.ls Logo

HighPoint RocketRAID 3700 Series - Page 29

HighPoint RocketRAID 3700 Series
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
Critical – missing disk
A disk has been removed or experienced failure, and user needs to reinsert disk or add a new disk.
Rebuilding
The array is currently rebuilding.
Verifying
The array is performing a data consistency check. Array status will show ‘verifying’.
Disabled
The array does not have enough disks to maintain the RAID level. A disabled array is not accessible.
OCE/ORLM
Array is expanding its capacity or migrating to a different raid level. Status will
display ‘Expanding/MigratingOCE/ORLM stopped
The ‘Expansion/Migrating process has been stopped. The status will display ‘Need
Expanding/Migrating’
Critical – OCE/ORLM
A disk member is lost during the OCE/ORLM process.
Critical – OCE/ORLM - rebuild
The expanding/migrating array requires a rebuild.