3.3.1 Set Thermometry Parameters
Congure the parameters of temperature measurement.
Steps
1.
Go to Conguraon → Local , enable Display Temperature Info. .
Display Temperature Info.
Select Yes to display temperature
informaon on live view.
Enable Rules to display the rules informaon on live view.
2.
Click Save.
3.
Go to
Conguraon → Temperature Measurement → Basic Sengs to congure parameters.
Enable Temperature Measurement
Check to enable temperature measurement funcon.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature informaon on the stream.
Display Max./Min./Average Temperature
Check to display maximum/minimum/average temperature informaon on live view when
the temperature measurement rule is line or area.
Posion of Thermometry Info
Select the posion of temperature informaon showed on the live view.
Near Target: display the informaon beside the temperature measurement rule.
Top Le: display the informaon on the top le of screen.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Opcal Transmissivity
Set the opcal transmissivity of external opcal material (e.g.: germanium window) to
improve the temperature measuring accuracy.
Calibraon Coecient
Check to enable it and set the value of calibraon coecient to get the temperature of the
external window or
opcal material automacally. The seng range is 0 to 30.
Note
You can get the seng value from SDK soware.