3.3.1 Set Thermometry Parameters
Congure the parameters of temperature measurement.
Steps
1.
Go to Conguraon → Local , enable Display Temperature Info. .
Display Temperature Info.
Select Yes to display temperature
informaon on live view.
Enable Rules to display the rules informaon on live view.
2.
Click Save.
3.
Go to
Conguraon → Temperature Measurement → Basic Sengs to congure parameters.
Enable Temperature Measurement
Check to enable temperature measurement funcon.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature informaon on the stream.
Display Max./Min./Average Temperature
Check to display maximum/minimum/average temperature informaon on live view when
the temperature measurement rule is line or area.
Posion of Thermometry Info
Select the posion of temperature informaon showed on the live view.
●
Near Target: display the informaon beside the temperature measurement rule.
●
Top Le: display the informaon on the top le of screen.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range.
Opcal Transmissivity
Set the opcal transmissivity of external opcal material (e.g.: germanium window) to
improve the temperature measuring accuracy.
Calibraon Coecient
Check to enable it and set the value of calibraon coecient to get the temperature of the
external window or
opcal material automacally. The seng range is 0 to 30.
Note
You can get the seng value from SDK soware.
Thermographic Cube Camera User Manual
9