EasyManuals Logo

Hikmicro HM-TD3117T-1/Q User Manual

Hikmicro HM-TD3117T-1/Q
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
9.3 Port Mapping
By seng port mapping, you can access devices through the specied port.
Before You Start
When the ports in the device are the same as those of other devices in the network, refer to
Port
to modify the device ports.
Steps
1.
Go to
Conguraon → Network → Basic Sengs → NAT .
2.
Select the port mapping mode.
Auto Port Mapping Refer to Set Auto Port Mapping for detailed informaon.
Manual Port Mapping Refer to Set Manual Port Mapping for detailed informaon.
3.
Click Save.
9.3.1 Set Auto Port Mapping
Steps
1.
Check Enable UPnP™, and choose a friendly name for the camera, or you can use the default
name.
2.
Select the port mapping mode to Auto.
3.
Click Save.
Note
UPnP™ funcon on the router should be enabled at the same me.
9.3.2 Set Manual Port Mapping
Steps
1.
Check Enable UPnP™, and choose a friendly name for the device, or you can use the default
name.
2.
Select the port mapping mode to Manual, and set the external port to be the same as the
internal port.
3.
Click Save.
What to do next
Go to the router port mapping
sengs interface and set the port number and IP address to be the
same as those on the device. For more
informaon, refer to the router user manual.
Thermographic Cube Camera User Manual
31

Table of Contents

Other manuals for Hikmicro HM-TD3117T-1/Q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hikmicro HM-TD3117T-1/Q and is the answer not in the manual?

Hikmicro HM-TD3117T-1/Q Specifications

General IconGeneral
BrandHikmicro
ModelHM-TD3117T-1/Q
CategoryThermographic Cameras
LanguageEnglish

Related product manuals