Temperature Sudden Increase and OFF are selectable. When the temperature change value
in the drawn area exceeds the set alarm threshold, the device triggers an alarm.
Cycle
Set the recording period of the temperature change.
Sudden Change Alarm Value
Set the temperature change alarm threshold for the rule. When the dierence between the
max. temperature and the min. temperature in the recording cycle exceeds the set alarm
value, the device triggers an alarm.
5.
You can shield certain area from being detected. Refer to
Set Shielded Region for detailed
sengs.
6.
Click Save.
Click Live View, and select thermal channel to view the temperature and rules informaon on
live view.
Point Thermography
Congure the temperature measurement rule and click any point in live view to monitor the
temperature.
Steps
1.
Click in the live view and a cross cursor showed on the interface.
2.
Drag the cross cursor to desired
posion.
Go to Live View interface to view the temperature and rule of the point in thermal channel.
Line Thermography
Congure the temperature measurement rule and monitor the maximum temperature of the line.
Steps
1.
Click and drag the mouse to draw a line in the live view interface.
2.
Click and move the line to adjust the
posion.
3.
Click and drag the ends of the line to adjust the length.
Go to Live View interface to view the maximum temperature and rule of the line in thermal
channel.
Area Thermography
Congure
the temperature measurement rule and monitor the maximum temperature of the area.
Steps
1.
Click and drag the mouse in the liveview to draw the area and right click to nish drawing.
2.
Click and move the area to adjust the posion.
Thermographic Cube Camera User Manual