EasyManua.ls Logo

HikRobot CameraLink - Line Trigger Configuration; Setting Trigger Source for Line Trigger

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CameraLink Line Scan Camera·User Manual
18
Figure 6-5 Set Frame Trigger Parameter
3. Select Line Start as Trigger Selector, and On as Trigger Mode.
Figure 6-6 Set Line Trigger Parameter
4. Select different line trigger signals as Trigger Source according to actual demands.
Figure 6-7 Set Trigger Source for Line Trigger
5. Select Trigger Activation according to actual demands.
Rising Edge refers to the rising edge of the trigger signal is valid, that is camera exposure and
acquisition at the beginning of the rising edge of the trigger signal, and the whole process will
stop when the camera acquires the line signal that is able to output a complete frame.
Falling Edge refers to the falling edge of the trigger signal is valid, that is camera exposure and
acquisition at the beginning of the falling edge of the trigger signal, and the whole process will
stop when the camera acquires the line signal that is able to output a complete frame.
If the line trigger frequency exceeds the camera limit, the camera cannot respond.

Table of Contents

Related product manuals