CameraLink Line Scan Camera·User Manual
31
Sensor
exposure
Exposure 1 Exposure 2 Exposure 3
Trigger_in 1
Trigger
delay
Trigger_in 2
Trigger
delay
Trigger_in 3
Trigger
delay
Figure 6-27 Signal Delay Sequence Diagram
You can set proper value in Trigger Delay, and its range is 0 μs to 16000000 μs.
Figure 6-28 Set Trigger Delay
6.4.3 Trigger Activation
The camera supports trigger acquisition in the rising edge or falling edge of external signal. The
principle and parameter of trigger activation are shown below.
Table 6-4 Trigger Activation Principle and Parameter
Trigger Activation
Parameter
Parameter Value
Principle
Rising edge
Acquisition Control >
Trigger Activation
Rising Edge
Rising Edge refers to the rising
edge of the trigger signal is
valid, that is camera exposure
and acquisition at the beginning
of the rising edge of the trigger
signal.
Falling edge
Acquisition Control >
Trigger Activation
Falling Edge
Falling Edge refers to the falling
edge of the trigger signal is
valid, that is camera exposure
and acquisition at the beginning
of the falling edge of the trigger
signal.