CameraLink Line Scan Camera·User Manual
36
The Line Inverter parameter is disabled by default.
7.2.2 Enable Strobe Signal
The strobe signal is used to directly output I/O signal to external devices when camera’s event
source occurs. You can enable strobe signal as shown below.
Click Digital IO Control, set Exposure Start Active as Line Source, and enable Strobe Enable.
The camera currently supports setting exposure start active as line source only.
Figure 7-3 Enable Strobe Signal