EasyManua.ls Logo

HikRobot CameraLink - Frame Trigger Settings; Setting Trigger Source for Frame Trigger

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CameraLink Line Scan Camera·User Manual
20
Figure 6-10 Set Trigger Source for Frame Trigger
5. Select Trigger Activation according to actual demands.
Rising Edge refers to the rising edge of the trigger signal is valid, that is camera exposure and
acquisition at the beginning of the rising edge of the trigger signal, and the whole process will
stop when the camera acquires the line signal that is able to output a complete frame.
Falling Edge refers to the falling edge of the trigger signal is valid, that is camera exposure and
acquisition at the beginning of the falling edge of the trigger signal, and the whole process will
stop when the camera acquires the line signal that is able to output a complete frame.
Level High refers to the level high of the trigger signal is valid. The trigger is active as long as
the trigger signal is high.
Level Low refers to the level low of the trigger signal is valid. The trigger is active as long as the
trigger signal is low.
The camera provides Frame Burst Start trigger mode, which receives a trigger signal to output
multiple lines of image.
Go to Acquisition Control > Acquisition Burst Frame Count to set image number of frame trigger,
ranging from 1 to 1023. The sequence diagram of frame trigger is shown below.

Table of Contents

Related product manuals