EasyManua.ls Logo

HikRobot CameraLink - Page 69

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CameraLink Line Scan Camera·User Manual
59
Current
Parameter
User
Parameter 1
User
Parameter 2
User
Parameter 3
Device
Default
Parameter
load
save
load
Figure 10-5 Parameter Relation
You can save parameters, load parameters and set user default as shown below.
Save Parameters
Steps:
1. Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2. Click Execute in User Set Save to save parameters.
Figure 10-6 Save User Set
Load Parameters
Steps:
1. Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2. Click Execute in User Set Load to load parameters to the camera, as shown below.

Table of Contents

Related product manuals