CameraLink Line Scan Camera·User Manual
66
x:
0—off
14—ObliqueMonoBar
16—GradualMonoBar
Set test pattern. Eg. w
TestPattern 14.
AcquisitionLineRat
e (ControlEnable)
w AcquisitionLineRate x
or y
x: it refers to the
written line rate value
and enable line rate
y: it refers to the line
rate value you want
to set (you can write
directly, and disable
line rate when
writing)
x=y+1073741824
Set line rate (enable).
Eg. w AcquisitionLineRate
1073841824, it means setting
line rate as 100000, and
enabling line rate.
Eg. w AcquisitionLineRate
100000, it means setting line
rate as 100000, and disabling
line rate.
When value is larger
than 10737441824,
line rate is enabled
Read line rate:
If line rate is enabled, you
reading and writing x are
available, and line rate is
y=x-1073741824.
If line rate is disabled, the
reading value is y.
Read final (actual) line rate.
x=read value
y=value shown in MVS
y= x/10000
Read final (actual) line rate.
Set trigger mode. Eg: w
TriggerMode 64.
Set the CC1 trigger. Eg. w