Control Panel User Manual
140
A
1) Please check if the network status indicator of the board is normal on;
2) If the network status indicator is not normal on, please check if the
network cable connection is normal.
Q: What if the client cannot log in the device?
A: Troubleshoot according to the prompt.
Please check if the device IP Address and Port No. are correct. The device
default IP Address is: 192.0.0.64, and the Port No. is: 8000.
Please check if the user name and password to log in the control panel are
correct. The default user name is: admin, the word is: 12345.
Q: Why the control panel cannot communicate with the alarm center group?
A: The configuration of control panel communicating with the alarm center group
is as follows:
1) If the user communicates with the center via LAN: Configure parameters
such as monitoring IP, Port No., User Account and Communication
Protocols of the remote alarm center in Remote Configuration-> Others->
Network Center Configuration;
2) If the user communicates via dialing: Configure parameters such as phone
number, receiver identity account and communication protocols of the
remote alarm center in Remote Configuration-> Others-> Dialing
Parameter Setting;
3) If the user communicates via WIFI: Configure APN Name and Parameters
of remote alarm center in Remote Configuration-> Others-> WIFI
Parameter Setting. The parameters include monitoring IP, Port No., User
Account and Communication Protocol, etc.;
4) After setting dialing parameters, LAN parameters and WIFI parameters,
configure the uploading mode in Remote Configuration-> Uploading
Mode Configuration
Q: How to configure the communication way of control panel and alarm center
group?
A: