Control Panel User Manual
74
No.1~No.8.
{11} End the command.
Prior Schedule Time Parameter Configuration
To configure the time parameters of the prior schedule, please refer to the
command below.
696 00 0 0 0 0 0 0 0 0 0 E #
1
2 4 63 5
87
9
10
11 12
13
{1} Prior Schedule Time Parameter Configuration Command Address:
696.
{2} It indicates the prior schedule number. 01~30 indicate prior
schedule No.1~No.30.
{3} It presents the time bucket composed by {4}~{11}. The value range
is 1~8.
{4}~{11} It indicates the start time and end time during the time bucket
of {3}.
Start Time: {4}{5}:{6}{7}
End Time: {8}{9}:{10}{11}
When you set the start and end time as 00:00 and 00:00, all the
settings from the present time bucket to the maximum time bucket
will be cleared.
When you set the start and end time as non-zero, the previous time
bucket must be non-zero.
When you set the start and end time as non-zero, only Arming in
{12} can be set.
When you set the start and end time as non-zero, end time must be
greater than start time in every time bucket.