Check the parameter to enable spare ARC.
Spare ARC IP Address
Enter the IP Address of the spare ARC.
Spare ARC Port
Enter the spare ARC port number.
RS-232
Used for communicaon between the Hik IP Receiver Pro and ARC.
Serial Port
By default, the serial port is COM1.
Baud Rate
Keep it the same with the baud rate set on ARC.
Data Bit
Keep it the same with the data bit set on ARC.
Parity
Keep it the same with the parity set on ARC.
Stop Bit
It cannot be edited and is 2 by default.
Compability
The versions of Sur-Gard protocol.
Receiver Number
The number used for marking the Hik IP Receiver Pro as an informaon receiver. You can
customize this parameter. Keep it the same with the number set on ARC.
Line Card Number
The number of the line used for communicaon between the Hik IP Receiver Pro and ARC.
You can customize this parameter. Keep it the same with the number set on ARC.
Heartbeat
If you select Sur-Gard as the protocol type, check Enable Hik IP Receiver Pro Heartbeat to
enable heartbeat between the ARC and the Hik IP Receiver Pro.
Hik IP Receiver Pro Heartbeat Interval
It ranges from 10 to 65535 seconds. It is 30 seconds by default.
Device Heartbeat Interval
It ranges from 10 to 86400 seconds. It is 30 seconds by default.
Hik IP Receiver Pro User Manual
37