Right click on the map link in edit state to pop-up the right button menu .
Click [Property] to pop-up tips Figure 5-9. Change the name of the map link in the [Name]
bar. Re-select the associated map in [Associate] camera list. Click [OK] to modify the map
link or click [Cancel] to cancel the modify operation.
Note: Double click the added map link in Map Preview Area in non-editing state can
directly turn to the associated map of the map link.
5.1.4 Alarm Spot Operation
Alarm spot: The associated alarm input of an area in the map. (Such as: Audio sensors,
Infrared sensors.)
(1)Add alarm spot
Click the [Add alarm spot] button in edit state to pop-up the dialog.
(Figure 5-10) Input the name of hop spot in the [Name] bar and select the associated
alarm input port in [Associate] port list (See 6.7.3 Alarm box and alarm in/out
configuration for detail). Click [OK] to add the alarm spot.
Figure 5-10 Add alarm spot