EasyManua.ls Logo

Hioki BT3563A User Manual

Hioki BT3563A
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BT3563A
Instruction Manual
BATTERY HiTESTER
EN
Jan. 2021 Revised edition 9
BT3562A981-09 21-01H
Be sure to read this manual before using the instrument.
p.3
When using the instrument for the
rst time
Troubleshooting
Names and Functions of Parts
p.11
Maintenance and Service
p.189
Measurement Preparations
p.19
Error Display
p.191
BT3562A
BT3561A
BT3563
BT3563-01
BT3562
BT3562-01
HIOKI BT3562A981-09

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Hioki BT3563A and is the answer not in the manual?

Hioki BT3563A Specifications

General IconGeneral
DisplayLCD
Measurement ParameterResistance, Voltage
Test Current1 mA
InterfaceUSB, RS-232C
Operating Temperature0°C to 40°C
Dimensions215 mm

Summary

Chapter 1 Overview

1.1 Product Overview

Introduces the instrument's function and application.

1.2 Features

Highlights key capabilities and specifications of the instrument.

1.3 Names and Functions of Parts

Details the front panel components and their functions.

1.4 Menu Display Sequence (SHIFT  ENTER)

Outlines the steps for accessing and navigating menu settings.

1.5 Measurement Flowchart

Provides a step-by-step guide for basic measurement procedures.

Chapter 2 Measurement Preparations

2.1 Preparation Flowchart

Illustrates the initial steps for setting up the instrument.

2.2 Connecting the Power Cord

Explains how to safely connect the power supply to the instrument.

2.3 Connecting the Optional Test Leads

Details the procedure for connecting measurement test leads.

2.4 Turning the Power On and Off

Describes how to power the instrument on, off, and place it in standby mode.

2.5 Selecting the Line Frequency

Explains how to set the power supply frequency to minimize noise.

Chapter 3 Measurement

3.1 Pre-Operation Inspection

Guides through essential checks before using the instrument.

3.2 Basic Measurement Example

Demonstrates a practical example of measuring resistance and voltage.

3.3 Selecting Measurement Mode

Explains how to choose between different measurement modes.

3.4 Setting Measurement Range

Details how to select appropriate measurement ranges.

3.5 Setting Sampling Rate

Describes how to adjust the sampling rate for measurement precision.

3.6 Zero-Adjust Function

Explains how to perform zero adjustment to improve measurement accuracy.

3.7 Displaying Measurement Results

Shows how measured resistance and voltage values are displayed.

Chapter 4 Applied Measurement

4.1 Comparator Function

Allows setting thresholds for automatic pass/fail judgments of measurements.

4.2 Trigger Function

Manages measurement initiation based on internal or external signals.

4.3 Measurement Current Pulse Output Function

Addresses interference by pulsing measurement current during operation.

4.4 Averaging Function

Minimizes display instability by averaging multiple measurement values.

4.5 Statistical Calculation Functions

Calculates mean, std dev, capability indices for up to 30000 measurements.

4.6 Memory Function

Stores up to 400 measurement values in internal memory for later download.

4.7 Key-Lock Function

Disables front panel keys to prevent accidental changes to settings.

4.8 Panel Save Function

Saves current measurement settings to non-volatile memory.

4.9 Panel Load Function

Reloads previously saved measurement configurations.

4.10 Self-Calibration

Adjusts internal circuitry offset and gain for improved measurement precision.

4.11 Measurement Value Output Function

Outputs measured values via RS-232C or LAN based on trigger input.

4.12 Key Beeper Setting

Controls audible feedback when front panel keys are pressed.

4.13 Reset Function

Resets instrument settings to factory defaults.

Chapter 5 External Control (EXT I/O)

5.1 Overview

Introduces external control capabilities and input/output functions.

5.2 Signal Descriptions

Details pinouts, input/output signals, and their functions.

5.3 Timing Chart

Illustrates signal timing for external trigger and internal trigger operations.

5.4 Internal Circuitry

Provides block diagrams of internal circuits for input and output signals.

5.5 External Control Q&A

Answers common questions regarding external control and connections.

Chapter 6 Printing

6.1 Connecting the Printer

Guides on connecting a printer to the instrument for output.

6.2 Selecting the Interface

Details how to select the appropriate interface for printing.

6.3 Printing

Explains how to print measurement values and statistical results.

Chapter 7 Analog Output

7.1 Connecting Analog Output

Describes how to connect cables for analog output of measured values.

7.2 Analog Output Specifications

Lists specifications for the analog output function.

Chapter 8 RS-232C/GP-IB/LAN Interfaces

8.1 Overview and Features

Introduces the available communication interfaces and their features.

8.2 Specifications

Provides detailed specifications for RS-232C, LAN, and GP-IB interfaces.

8.3 Selecting the Connections and Protocol

Guides on physically connecting and configuring communication interfaces.

Chapter 9 Specifications

9.1 Basic Specifications

Lists fundamental operational and performance specifications of the instrument.

9.2 Accuracy

Details the guaranteed accuracy conditions and error limits.

9.3 General Specifications

Covers environmental, power, dimensions, and safety specifications.

Chapter 10 Maintenance and Service

10.1 Troubleshooting

Provides solutions for common operational issues and malfunctions.

10.2 Cleaning

Instructions for cleaning the instrument's exterior.

10.3 Error Display

Explains various error codes and their meanings.

Chapter 11 License Information

Appendix 1 Precautions for Making Custom Test Leads

Appendix 2 AC Four-terminal Method

Appendix 3 Measurement values when using four-terminal measurement (Differences in measurement values due to measurement leads used)

Appendix 4 Synchronous Detection System

Appendix 5 Configuration and Extension of the Test Leads

Appendix 6 Effect of Eddy Currents

Appendix 7 Calibration Procedure

Appendix 8 Zero Adjustment

Appendix 9 Test Lead Options

Appendix 10 Rack Mounting

Appendix 11 Dimensional Diagram