Test Equipment
3522-50
Hioki 3522-50 User Manual
5
of 1
of 1 rating
204 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Instruction
Ma
nual
For..
.
は専用機種。複数の場合
は「
/
」で
区切る。
不要の場合はと
る。
形名を入力。
複数の場
合は
「
/
」
で区切る。
3522-50
品名を入力
。
LCR
HiTESTER
June
2011
Rev
ised
edition
7
3522C981-07
11-06H
2
Table of Contents
Default Chapter
3
Table of Contents
3
Shipping Check
10
Safety
11
Points for Attention During Use
13
Layout of this Manual
14
Chapter 1 Overview
15
Product Overview
15
Product Features
16
Names and Functions of Parts
17
Chapter 2 Before Starting Measurement
21
Connecting the Power Cord
21
Connecting the Test Leads
22
Establishing the Connections
22
Turning the Power on and off
24
Chapter 3 Outline of Operation
25
About the Touch Panel
25
About the Screen
26
Control Screen Sequence
28
Basic Measurement
29
Basic Flow up to Testing of the Sample
29
Setting the Test Parameters to be Displayed (Cs, D)
30
Setting the Test Frequency
32
Setting the Constant Voltage Level
35
Setting Open Circuit Compensation
37
Setting Short Circuit Compensation
40
Starting Testing
42
Chapter 4 Detailed Description of Functions
43
Description of the Screens
43
The Initial Screen
44
The Menu Screen and Application Menu Screen
45
Setting the Parameters to be Displayed
46
Control Screen Sequence
46
Details of the Setting Process
46
Series Equivalent Circuit Mode and Parallel Equivalent Circuit Mode
48
Setting the Test Frequency
49
Control Screen Sequence
49
Selecting the Input Method
50
Input Using the Ten Key Screen
51
Input Using the Digit Screen
52
Setting the Test Signal Level
53
Control Screen Sequence
53
Selecting the Level Type
54
Setting the Open Circuit Voltage (V) Level
56
Setting the Constant Voltage (CV) Level
57
Setting the Constant Current (CC) Level
58
Setting the Voltage/Current Limit
59
Control Screen Sequence
59
Details of the Setting Process
60
Setting the Ranging
62
Control Screen Sequence
62
Setting the Ranging
63
Setting AUTO Ranging
63
Setting the Ranging to HOLD
64
Open Circuit Compensation
66
Control Screen Sequence
66
Setting the Compensation Method
67
ALL Compensation
68
Spot Compensation
70
When an Error Message Appears and Compensation Has Stopped
73
Clearing Compensation Data
73
Short Circuit Compensation
74
Control Screen Sequence
74
Setting the Compensation Method
75
ALL Compensation
77
Spot Compensation
79
When an Error Message Appears and Compensation Has Stopped
82
Clearing Compensation Data
82
Open Circuit Compensation and Short Circuit Compensation
83
Setting the Trigger
85
Control Screen Sequence
85
Details of the Setting Process
86
Setting the Trigger Delay
88
Control Screen Sequence
88
Details of the Setting Process
89
Setting Averaging
91
Control Screen Sequence
91
Details of the Setting Process
92
Setting the Testing Speed
94
Control Screen Sequence
94
Details of the Setting Process
95
Setting and Activating the Comparator
96
Control Screen Sequence
97
Setting the Comparator
97
Returning from Comparator Operation to Normal Testing
100
Choosing How to Set the Upper and Lower Limit Values
100
Setting the Upper or Lower Limit Value as an Absolute Value (ABS)
102
Setting the Upper or Lower Limit Value as a Percentage (%) Relative to a Standard Value
104
Displaying Measurement Values as Deviations from the Reference Value (Δ%)
107
Setting and Activating the Scaling
109
Control Screen Sequence
109
Setting Scaling
110
Canceling the Scaling Function
111
Setting the Compensation Coefficient (A, B)
112
Panel Save Function
114
Control Screen Sequence
114
Details of the Setting Process
115
Panel Load Function
118
Control Screen Sequence
118
Details of the Setting Process
119
Setting the Beep Sound
121
Control Screen Sequence
121
Details of the Setting Process
122
Enlarged Display of Measurement Values
123
Control Screen Sequence
123
Details of the Setting Process
124
System Reset
125
Control Screen Sequence
125
Details of the Setting Process
126
Continuous Test Function
128
Control Screen Sequence
128
Details of the Setting Process
129
External DC Bias Setting
132
Control Screen Sequence
132
Details of the Setting Process
133
Setting the Number of Displayed Digits
134
Control Screen Sequence
134
Details of the Setting Process
135
Setting for Display
136
Control Screen Sequence
136
Details of the Setting Process
137
Key Lock Function
138
Turning the Key Lock on and off
138
Chapter 5 Applications
139
Example of Comparator Application
139
Testing High Impedance Elements
141
Testing an Element in a Circuit
142
External Interference
143
Countermeasures against Interference from the Power Supply Line
143
Countermeasures against Noise from the Test Cables
145
The EXT I/O Connector
146
Pinouts for the EXT I/O Connector
147
Signal Lines for the EXT I/O Connector
148
Circuit Construction and Connections for the EXT I/O Connector
150
Electrical Characteristics of the Output Signals
151
Testing Using EXT I/O
152
Normal Testing
152
Continuous Testing from EXT I/O
154
Supplying DC Bias
159
How to Supply a DC Bias Voltage
159
How to Supply a DC Bias Current
161
The Residual Charge Protection Function
162
9442 PRINTER (Option)
163
Preparation
163
Connection Method
165
Control Screen Sequence
166
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Hioki 3522-50 and is the answer not in the manual?
Ask a question
Hioki 3522-50 Specifications
General
Type
LCR Meter
Measurement Parameter
Z, L, C, R, D, Q, θ
Display
LCD
Interfaces
RS-232
Power Supply
AC 100-240 V, 50/60 Hz
Related product manuals
Hioki 3554
168 pages
Hioki 3541
194 pages
Hioki 3551
32 pages
Hioki 3560
156 pages
Hioki 3288
1 page
Hioki 3158
136 pages
Hioki 3803
102 pages
Hioki 3159
188 pages
Hioki 3244-60
2 pages
Hioki 3030-10
2 pages
Hioki 3454-11
10 pages
Hioki MO HiTESTER 3452
90 pages