140
────────────────────────────────────────────────────
5.6 Testing Using EXT I/O
────────────────────────────────────────────────────
5.6.2 Continuous Testing From EXT I/O
Page Panel numbers
1
2
3
4
5
6
1- 5
6-10
11 - 15
16 - 20
21 - 25
26 - 30
Save the test conditions
for continuous testing
Testing start
Shift to the continuous
test screen
Specify the panel number
It is possible to read in from the EXT I/O connector in order test conditions
which have been saved using the panel save function, and to perform as
many measurements as desired one after another automatically (continuous
testing).
Up to five panel numbers can be selected in a page for the continuous
testing.
(1) Control Screen Sequence
Section 4.16, "Panel Save Function"
Section 4.21, "Continuous Test Function"
Specify the panel number for use the LD1
----------
to LD5
----------
and PNL0
---------------
to PNL2
---------------
signals of the EXT I/O
connector.
Input the TRIG
---------------
signal of the EXT I/O connector to
start test.