Do you have a question about the Hioki BT3561A and is the answer not in the manual?
Display | LCD |
---|---|
Power supply | 100 to 240 V AC, 50/60 Hz, 50 VA max. |
Relative Humidity | 80% RH or less (no condensation) |
Measurement parameters | Resistance, Voltage |
Measurement current | 1 mA to 1 A |
Test Current | 1 mA to 1 A (depending on range) |
Interface | USB, RS-232C |
Dimensions | 210 x 100 x 50 mm |
Operating Temperature | 0 to 40 °C |
Storage Temperature | -10 to 50 °C |
Identifies and explains the function of each key and terminal on the instrument's front panel.
Explains the function of each operating key, including primary and secondary functions.
Details the procedure for safely connecting the instrument to a power source.
Explains how to connect the four-terminal test leads to the instrument's input terminals.
Describes the correct procedure for turning the instrument's main power on and placing it in standby mode.
Outlines essential checks to ensure the instrument is operating correctly before measurement.
Explains how to perform zero-adjustment to ensure measurement accuracy.
Explains how to set resistance and voltage measurement ranges, including auto-ranging.
Explains the purpose and procedure for zero adjustment to nullify offset voltage.
Describes indicators and causes of measurement faults, such as open leads or high contact resistance.
Introduces the comparator function for judging measurements against preset thresholds.
Demonstrates setting upper/lower thresholds for resistance and voltage with beeper feedback.
Illustrates setting reference value and tolerance for resistance and voltage with beeper feedback.
Explains how to use internal and external triggers to control measurement initiation.
Details the calculation of mean, standard deviation, and process capability indices for up to 30000 values.
Describes storing up to 400 measurement values internally for later download via communication commands.
Details the self-calibration function for adjusting offset voltage and gain drift to improve measurement precision.
Describes re-initializing settings to factory defaults, including optional panel data.
Details the pinout, input signals, and output signals for the EXT I/O connector.
Explains how to attach connectors and select protocols for RS-232C, LAN, and GP-IB interfaces.
Guides the user through selecting RS-232C, LAN, or GP-IB, and configuring related settings.
Explains message formats, terminators, separators, and data formats for instrument communication.
Details fundamental specifications including measurement items, ranges, modes, and input/output ratings.
Provides guaranteed accuracy conditions, including temperature, humidity, and warm-up time.
Lists common symptoms, check items, and countermeasures for instrument malfunctions.