EasyManua.ls Logo

Hirschmann HiSecOS EAGLE20 - Page 245

Hirschmann HiSecOS EAGLE20
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Switching > Global
Switching
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
245
Buttons
Aging Time [s] Specifies the aging time in seconds.
Possible values:
10..500000
(default setting
30
)
The device monitors the age of the learned unicast MAC addresses. The
device deletes address entries that exceed a particular age (aging time)
from its address table (Forwarding Database).
You find the address table in the
Switching > Filter for MAC Addresses
dialog.
Activate Flow
Control
Activates/deactivates the flow control globally in the device.
Possible values:
unmarked
(default setting)
The flow control is inactive in the device.
marked
The flow control is active in the device.
Additionally activate the flow control on the required ports, see the
Basic
Settings > Port
dialog, "Configuration" tab, checkbox in the "Flow
Control" column.
Button Meaning
Set Transfers the changes to the volatile memory (
RAM
) of the device and
applies them to the device. To save the changes in the non-volatile
memory, proceed as follows:
Open the
Basic Settings > Load/Save
dialog.
In the table, highlight the desired configuration profile.
If in the "Selected" column the checkbox is
unmarked
, click the
"Select" button.
Click the "Save" button.
Reload Updates the fields with the values that are saved in the volatile memory
(
RAM
) of the device.
Help Opens the online help.
Parameters Meaning

Table of Contents

Related product manuals