Monitoring correct Operation
In the table you specify the parameters that the device monitors. The
device signals the occurrence of an event by opening the signal contact.
Parameters Meaning
Temperature Activates/deactivates the monitoring of the temperature in the device.
Possible values:
marked
(default setting)
Monitoring is active.
The signal contact opens if the temperature exceeds / falls below the
threshold values.
unmarked
Monitoring is inactive.
You specify the temperature thresholds in the
Basic Settings > System
dialog, in the "Temperature (°C)" field.
Connection Error Activates/deactivates the monitoring of the port/interface link.
Possible values:
marked
Monitoring is active.
The signal contact opens if the link interrupts on a monitored
port/interface.
In the "Port" tab, you have the option of selecting the ports/interfaces
to be monitored individually.
unmarked
(default setting)
Monitoring is inactive.
External memory
removed
Activates/deactivates the monitoring of the active external memory.
Possible values:
marked
Monitoring is active.
The signal contact opens if you remove the active external memory
from the device.
unmarked
(default setting)
Monitoring is inactive.
You specify the active external memory in the
Basic Settings >
Load/Save dialog, "External Memory" frame.