EasyManua.ls Logo

Hirschmann MICE MS20-0800 Series - Page 22

Hirschmann MICE MS20-0800 Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Installation MS20/MS30
Release
11
07/2013
They differ with regard to the number of interfaces and the media type. The
different interfaces of the media modules provide you with the following
interface-specific functions:
Specific functions of TP/TX interface
Link Control
Auto Polarity Exchange
Autonegotiation
Autocrossing (device may be connected with a crossed-over or an un-
crossed cable)
Specific functions of F/O interface
Link Down monitoring
Transceiver-specific (AUI-specific) functions
Collision recognition
Collision test (SQE)
Protection from permanent network connection (Jabber Control)
DTE Power Monitor
MM2 media modules
MM2 media modules
Module type
TP ports
10/100
Mbit/s
F/O port
multi-mode
10 Mbit/s
F/O port
multi-mode
100 Mbit/s
F/O port
single-
mode 1300
nm, 100
Mbit/s
F/O port
single-
mode 1550
nm, 100
Mbit/s
MM2 - 4TX1 (- EEC)4, RJ45––––
MM2 - 2FLM4 2, ST
MM2 - 4FXM3 4, MTRJ
MM2 - 2FXM3 / 2TX1 2, RJ45 2, MTRJ
MM2 - 2FXM2 2, DSC
MM2 - 2FXS2 2, DSC
Table 3: Media connections per MM2 media modules (number and type)