16
Installation Octopus II
Release
06
10/2018
18 (hyphen) –
19 Temperature range V Standard −40 °F ... +140 °F
(−40 °C ... +60 °C)
T Extended −40 °F ... +158 °F
(−40 °C ... +70 °C)
20 ... 21 Supply voltage BB 2 voltage inputs for redundant power supply
Rated voltage
24 V DC
Connection type 5-pin M12 connector
HH 2 voltage inputs for redundant power supply
Rated voltage range
36 V DC ... 48 V DC
Connection type 5-pin M12 connector
FF 2 voltage inputs for redundant power supply
Rated voltage range
24 V DC ... 48 V DC
Connection type 5-pin 7/8" plug
M9 1 voltage input
Rated voltage range
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Connection type 3-pin, 7/8" connector
N9 1 voltage input
Rated voltage range
72 V DC ... 110 V DC
Connection type 4-pin, 7/8" connector
QQ 2 voltage inputs for redundant power supply
Rated voltage range
24 V DC ... 48 V DC
Connection type 4-pin, “T”-coded M12
power plug
PP PoE 2 voltage inputs for redundant power
supply
Rated voltage range
47 V DC ... 57 V DC
PoE+ 2 voltage inputs for redundant power
supply
Rated voltage range
53 V DC ... 57 V DC
Connection type 4-pin, “T”-coded M12
power plug
22 ... 23 Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 7 on page 18.
24 ... 25 Software packages 99 Reserved
26 ... 27 Customer-specific
version
HH Hirschmann standard
HA Hirschmann Angled
H1 Hirschmann Power Supply Side
Item Characteristic Characteri
stic value
Description
Table 6: Device name and product code