56
Installation Octopus II
Release
06
10/2018
EMC interference
immunity
Standard
applications
Navy
applications
Railway
applications
(trackside)
Railway
applications (in
vehicles)
Motor vehicle
applications
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge ±4 kV ±6 kV ±6 kV ±6 kV ±4 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge ±8 kV ±8 kV ±8 kV ±8 kV ±8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 3000 MHz max. 10 V/m max. 10 V/m max. 20 V/m max. 20 V/m max. 10 V/m
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
DC supply connection ±2 kV ±2 kV ±2 kV ±2 kV ±2 kV
EN 61000-4-4
IEEE C37.90.1
Data line ±4 kV ±4 kV ±2 kV ±2 kV ±2 kV
Voltage surges - DC supply connection
EN 61000-4-5 line/ground ±2 kV ±2 kV ±2 kV ±2 kV ±2 kV
EN 61000-4-5 line/line ±1 kV ±1 kV ±1 kV ±1 kV ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±1 kV ±1 kV ±2 kV ±2 kV ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V 10 V 10 V 10 V 10 V
Pulse magnetic field
EN 61000-4-9 300 A/m 300 A/m