Periodic Maintenance and Adjustment 8-29
value, recharge or replace battery. A service center can perform this
diagnosis
2. Check to see if the output voltage of the rectifier when the engine is
idling is lower than the specified value. A service center can perform this
diagnosis
3. Check to determine if the EFI system has problems. A service center
can perform this diagnosis
4
Engine backfires
1. Check for air leaks in the air filter or air inlet pipe. Replace if needed
2. Check to see if the connection between the exhaust pipe and engine or
the exhaust pipe and muffler has an air leak. Replace or repair if needed
3. Check grade of gasoline, if too low, engine may backfire.
5
Engine is hard to start at
lower temperatures.
1. Check battery voltage in cold weather. Battery may need to be
recharged.
2. If outside temperature is below 0º F, move the ATV to a warmer place.
Once ATV warms up it should start.