Location Name State Description
Red-Blink Fault. Max. temperature limit exceeded
or other warning.
Red-On Alarm.
7 Identify LED (LOCID) Blue-On The switch module is identified.
1 Gb/sec LAN Switch Module (40 ports)
Figure 1-35 1 Gb/sec LAN Switch Module (40 ports)
Table 1-18 1 Gb/sec LAN Switch Module Switches (40 ports), Indicators
and Connectors
Location Name State Description
1 LAN ports 1 to 8 Green-On Link established.
Green-Blink Link communication.
Amber-On Link failed.
2 Memory Card slot (MC) - Slot for an SD memory card.
3 Access LED (ACC) Green-On The SD memory card is accessed.
4 Reset switch (RST) - Press and hold for five seconds to reset
the LAN switch module.
5 Power LED (PWR) Green-On Powered-on, normal operation.
6 Status1 LED (ST1) Green-On Normal operation.
Green-Blink Power-on diagnosis or software
activation.
Red-Blink Fault. Max. temperature limit exceeded
or other warning.
Red-On Alarm.
7 Identify LED (LOCID) Blue-On The switch module is identified.