6.1.3. Control System Functional Description
COAXIAL RELAY
Communication
Control I/O
MAIN CM8001
CONTROL MODULE
MAIN EXCITER (NOT INCLUDED)
Exciter Status
RF: +1dBm
RF RF
BACKUP CM8001
CONTROL MODULE
(OPTIONAL)
BACKUP EXCITER (NOT INCLUDED)
Exciter Status
RF: +1dBm
RF
PA702MP / PA704MP
POWER AMPLIFIER
+8Vcc from MCCB (NOT USED TO MEDIUM POWER SERIES)
+15VCC - MCCB Source Monitor
(NOT USED TO MEDIUM POWER SERIES)
+50VCC - MCCB Source Monitor
(NOT USED TO MEDIUM POWER SERIES)
Forward Output Power Measure - Analog signal, from 0 to 4.5v
Reflected Output Power Measure - Analog signal, from 0 to 4.5v
Power Amplifier On/Off (5V means normal operation)
Mask Filter Alarm Temperature (5Vcc)
+8Vcc (Main Control Address) – 0Vcc (Backup Control Address)
AC Phase Alarm - 5V means normal operation
Dummy Load Drawer Fan Alarm - 5V means normal operation
Exciter Status - Digital signal - 5V means normal operation
Control I/O Connector
MOD Control Rear Panel
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
B10
B1 B2 B3 B4 B5 B6 B7 B8 B9 B10
B10