EasyManua.ls Logo

Hitachi E-Compact Medium Power Series - Activation

Hitachi E-Compact Medium Power Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84 | 106
E-Compact Medium Power
2. Activation.
The steps of this activation must be followed to avoid damage to the equipment.
1
st
Before Turn-On, Check if all on/off key
Drawers it’s “off
2
nd
Trigger the circuit breaker on (01)
3
rd
Check if both the Exciter (Main and Backup) are
configured for the correct channel, the same as
the Mask Filter and the Antenna.
4
th
Check if both the Module Control CM8001 (Main
and Backup):
Chanel is the same of the Exciter (02)
The description of the Equipment is correct (03)
5
th
Check if the Main Exciter and Main Module
Control CM8001 are active.
6
th
Check if the Programmed Power in Main
Module Control CM8001 is 0 (ZERO) Watts:
Display Interface
>Measurements [2000] > Power [2100] >
Programmed Power [1/3]
7
th
Switch On the two Power Supplies (04) in the
MOD GV 40226 Drawer
8
th
Check the Drawer Communication Status.
In the Main Module Control Display Interface:
>Measurements [2000] > Communications
Status [2500]
Pxx = OK
9
th
Check the ALL Power Supply and Current when
0 (Zero) Watts Transmitter FWD Power:
In the Main Module Control Display Interface:
>Measurements [2000] > Drawers [2300]
> Power Supply [2310]
Power Supply ≈ 45,5V
>Measurements [2000] > Drawers [2300]
> Current [2320]
I ≈ 0,30A (for each PA)
01
MC8001 Display - Second Home Screen (Status)
02
03
04

Table of Contents