E-Compact Medium Power
6.6. Exciter Interface
The transmitters of the E-Compact Medium Power family have a monitoring interface for external exciters
to communicate with the CM8001 Control Module. There are two interfaces, one for the main driver and
one for the backup:
Control I/O In
Parameters
Status
P4
Exciter Status
Exciter Status to respective
CM 8001 Controler.
P9
VCC
+5 VCC
P9
P4
DB9 Male – Exciter Communication