8 Troubleshooting
308
SMGB0064 rev.0 - 08/2011
Model Motor model
Wire color for checking (normal value)
Red-Black White-Black Yellow-Black Blue-Black
RAS-4H(V)RNM2E (upper)
RAS-(4-6)H(V)RNM2E (lower)
SIC-65FV-D840-1 1 MΩ or greater 26~50kΩ 168~312kΩ 1 MΩ or greater
RAS-3HVRNM2E
RAS-(5-6)HVRNM2E (upper)
RAS-(5-6)HRNM2E (upper)
SIC-68FV-D851-7 1 MΩ or greater 42-78kΩ 168~312Ω 1 MΩ or greater
RAS-(8-12)HRNM (upper) SIC-61FV-D8138-1 1 MΩ or greater 42-78kΩ 168~312Ω 1 MΩ or greater
N O T E
- (*) Values are shown for referential purpose. While actual values may vary depending on the type of the
tester; any tester can be used to determine any short-circuit or breakage based on ∞ or several Ω/several
kΩ or 0Ω or ∞.
3. Coil resistance of electrical parts (Lower fan motor)
Part Name Model
Fan motor model/
Rated power
Wiring diagram Lead wire color
Resistance (Ω)
(at 20°)
Outdoor unit
lower fan motor
RAS-(8-10)HRNM SC121HSA/120W
Black Blue
Main winding
Thermo
Auxiliary winding
Red Orange White
Bet.Black-White
Bet.Blue-Red
Bet.Black-Blue
23.3 ± 10%
0.8 ± 10%
12.8 ± 10%
RAS-(8-12)HRNM SC230HSA/200W
Bet.Black-White
Bet.Blue-Red
Bet.Black-Blue
14.3 ± 10%
8.5 ± 10%
12.5 ± 10%
• Checking procedure for the ISPM
Rectication parts of internal circuit of ISPM (Common)
Remove all the terminals of the ISPM before check. If items (a)
to (h) are performed and the results are satisfactory, ISPM is
normal. Measure it under 1 kΩ range of a tester.
C A U T I O N
• Perform the high voltage discharge procedure as de-
scribed
• Do not use a digital tester.