70 
Applies a logic function to calculate [LOG] 
output state, 
Three options: 
[LOG] = A AND B 
[LOG] = A OR B 
[LOG] = A XOR B 
All  the  programmable  functions  available 
for logic (discrete) outputs except LOG1 to 
LOG3, OPO, no 
Applies a logic function to calculate [LOG] 
output state, 
Three options: 
[LOG] = A AND B 
[LOG] = A OR B 
[LOG] = A XOR B 
All  the  programmable  functions  available 
for logic (discrete) outputs except LOG1 to 
LOG3, OPO, no 
Applies a logic function to calculate [LOG] 
output state, 
Three options: 
[LOG] = A AND B 
[LOG] = A OR B 
[LOG] = A XOR B 
Sets response time of each input terminal,   
set range is (x 2 [ms]) to (x 2 [ms]) 
for (0 to 400 [ms]). 
Multistage speed/position 
determination time 
Set range is 0. to 200. (x 10ms) 
Overload warning 
processing cycle select 
Two option codes: 
40ms 
2ms 
Overload warning filter 
time constant 
Set the filter time constant for output 
current detection used for judgement of 
overload warning. 
Range is 0 to 9999 ms 
Overload warning 
hysteresis 
Set the hysteresis for overload warning 
signal. 
Range is 0 to 50% of the rated current of 
the inverter