- 14 -
Func.
Code
Name / Description
Default
-FE/-FU
Set
value
A045/
A245
V/f gain setting 100.
A051 DC braking enable
y
00 Disable
y
01 Enable
y
02 Freq.detection
00
A052 DC braking frequency setting 0.5
A053 DC braking wait time 0.0
A054 DC braking force during deceleration 0.
A055 DC braking time for deceleration 0.0
A056
DC braking / edge or level detection for [DB] input
y 00 Edge y 01 Level
01
A061/
A261
Frequency high limit setting 0.0
A062/
A262
Frequency low limit setting 0.0
A063
A065
A067
Jump (center) frequency setting 0.0
A064
A066
A068
Jump (hysteresis) frequency width setting 0.5
A071 PID enable
y 00 PID operation OFF
y 01 PID operation ON
00
A072 PID proportional gain 1.0
A073 PID integral time constant 1.0
A074 PID derivative time constant 0.00
A075 PV scale conversion 1.00
A076 PV source setting
y 00 [OI] terminal (current input)
y 01 [O] terminal (voltage input)
y 02 ModBus network
y 03 Calculate function output
00
A077 Reverse PID action
y 00 PID input = SP-PV
y 01 PID input = -(SP-PV)
00
A078 PID output limit 0.0
A081 AVR function select
y 00 AVR enabled y 01 AVR disabled
y 02 AVR enabled except during decel.
00
A082 AVR voltage select 230,400/
230,460
A085 Operation mode selection
y 00 Normal operation
y 01 Energy-saver operation
00
A086 Energy saving mode tuning 50.0
A092/
A292
Acceleration (2) time setting 15.0
A093/
A093
Deceleration (2) time setting 15.0
A094/
A294
Select method to switch to Acc2/Dec2 profile
y 00 2CH input from terminal
y 01 transition frequency
00
A095/
A295
Acc1 to Acc2 frequency transition point 0.0
A096/ Dec1 to Dec2 frequency transition point 0.0