EasyManua.ls Logo

Hitachi X200 Series - Page 268

Hitachi X200 Series
305 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The following table lists the holding registers for the “A” Group Standard Functions.
List of Holding Registers
Network Data
Func.
Code
Name R/W Description
Reg. Range Res.
A001 Frequency source
setting
R/W Five options; select codes:
00...Keypad potentiometer
01...Control terminal
02...Function F001 setting
03...ModBus network input
10...Calculate function output
1019h 0 to 3, 10
A002 Run command source
setting
R/W Three options; select codes:
01...Control terminal
02...Run key on keypad, or
digital operator
03...ModBus network input
101Ah 1, 2, 3
A003 Base frequency setting R/W Settable from 30 Hz to the
maximum frequency
101Bh 30 to max.
freq.
1 Hz
A203 Base frequency setting,
2nd motor
R/W Settable from 30 Hz to the 2nd
maximum frequency
150Ch 30 to max.
freq.2
1 Hz
A004 Maximum frequency
setting
R/W Settable from the base frequency
up to 400 Hz
101Ch 30 to 400 1 Hz
A204 Maximum frequency
setting, 2nd motor
R/W Settable from the 2nd base
frequency up to 400 Hz
150Dh 30 to 400 1 Hz
A005 [AT] selection R/W Five options, select codes:
00... Select between [O] and [OI]
at [AT]
02... Select between [O] and
keypad potentiometer
03... Select between [OI] and
keypad potentiometer
04... Only [O] input active
05... Only [OI] input active
101Dh 0, 2, 3,
4, 5
A011 O–L input active range
start frequency
R/W The output frequency
corresponding to the analog
input range starting point,
Range is 0.0 to 400.0
1020h 0 to 4000 0.1 Hz
A012 O–L input active range
end frequency
R/W The output frequency
corresponding to the analog
input range ending point, range
is 0.0 to 400.0
1022h 0 to 4000 0.1 Hz
A013 O–L input active range
start voltage
R/W The starting point (offset) for the
active analog input range, range
is 0. to 100
1023h 0 to 100 1 %
A014 O–L input active range
end voltage
R/W The ending point (offset) for the
active analog input range, range
is 0. to 100.
1024h 0 to 100 1 %
A015 O–L input start
frequency enable
R/W Two options; select codes:
00...Use offset (A011 value)
01...Use 0 Hz
1025h 0, 1
A016 External frequency
filter time constant
R/W Range n = 1 to 16, where n =
number of samples for average.
Set 17 to use 16-samples for avg.,
plus deadband +0.1/-0.2Hz
1026h 1 to 17 1 sample
B25