Warning and Error Messages
In case of an error, the screen will display the cause of the error and emit an audible sound.
REVERSE POLARRITY
Connection break
Reverse Polarity
CONNECT ERROR
CHECK MAIN POINT
BALANCE WIRES
NOT CONNECTED
INT. TEMP. TOO HI
OVER CHARGE
CAPACITY LIMIT
OVER TIME LIMIT
CONTROL FAIL
CELL ERROR
Incorrect polarity connected.
The battery connection is interrupted.
The battery connection is wrong.
The balance wires are not connected while
charging in balance mode.
The internal temperature of the unit is too high.
The battery capacity is more than the maximum capacity
set by the user.
The charging time is longer than the maximum charging
time set by the user.
Battery pack voltage is lower than 5 volts. The RDX2 Mini cannot
charge a pack with a voltage of less than 5v.
The balance connection is reading a di erent number of cells vs.
what was selected.