11
Assembly instructions
Linear Guideways
GW-04-0-EN-1910-MA
Rail length [mm] Accuracy class
C H P
– 50 12 6 2.0
50 – 80 13 7 3.0
80 – 125 14 8 3.5
125 – 200 15 9 4.0
200 – 250 16 10 5.0
250 – 315 17 11 5.0
315 – 400 18 11 6.0
400 – 500 19 12 6.0
500 – 630 20 13 7.0
630 – 800 22 14 8.0
800 – 1,000 23 16 9.0
1,000 1,200 25 18 11.0
1,200 1,300 25 18 11.0
1,300 1,400 26 19 12.0
1,400 1,500 27 19 12.0
1,500 1,600 28 20 13.0
1,600 1,700 29 20 14.0
1,700 1,800 30 21 14.0
1,800 1,900 30 21 15.0
1,900 2,000 31 22 15.0
Unit: µm
3.4 Parallelism
Parallelism of stop surfaces D and B of block and rail and parallelism of top of block C to mounting surface A of rail. Ideal
linear guideway installation is required, as is a measurement in the centre of the block.
Rail length [mm] Accuracy class
C H P SP UP
– 100 12 7 3 2 2
100 – 200 14 9 4 2 2
200 – 300 15 10 5 3 2
300 – 500 17 12 6 3 2
500 – 700 20 13 7 4 2
700 – 900 22 15 8 5 3
900 – 1100 24 16 9 6 3
1100 – 1500 26 18 11 7 4
1500 – 1900 28 20 13 8 4
1900 – 2500 31 22 15 10 5
2500 – 3100 33 25 18 11 6
3100 – 3600 36 27 20 14 7
3600 – 4000 37 28 21 15 7
Unit: µm
Table 3.2 Tolerance of parallelism between block and rail – HG, QH, EG, QE, CG, WE, QW, RG and QR series
Table 3.3 Tolerance of parallelism between block and rail – MG series