48
Lubrication
Assembly instructions
Linear Guideways
GW-04-0-EN-1910-MA
Size Initial lubrication partial quantity [cm
3
] Relubrication quantity [cm
3
]
Average load
(S)
Heavy duty
(C)
Super heavy duty
(H)
Average load
(S)
Heavy duty
(C)
Super heavy duty
(H)
15, 17 0.2 (3 ×) 0.3 (3 ×) — 0,2 0,3 —
20, 21 0.3 (3 ×) 0.5 (3 ×) 0.7 (3 ×) 0,3 0,5 0,7
25, 27 0.4 (3 ×) 0.8 (3 ×) 1.0 (3 ×) 0,4 0,8 1,0
30 0.6 (3 ×) 1.3 (3 ×) 1.7 (3 ×) 0,6 1,3 1,7
35 0.8 (3 ×) 1.9 (3 ×) 2.4 (3 ×) 0,8 1,9 2,4
45 — 3.8 (3 ×) 4.6 (3 ×) — 3,8 4,6
50, 55 — 6.3 (3 ×) 7.7 (3 ×) — 6,3 7,7
65 — 10.0 (3 ×) 13.5 (3 ×) — 10,0 13,5
Size Initial lubrication partial quantity [cm
3
] Relubrication quantity [cm
3
]
Average load (C) High load (H) Average load (C) High load (H)
MGN15 0.04 (3 ×) 0.06 (3 ×) 0,04 0,06
MGW15 0.07 (3 ×) 0.09 (3 ×) 0,07 0,09
Table 8.12 Lubricant quantities for grease lubrication – HG, QH, EG, QE, CG, WE, QW, RG, QR series
Table 8.13 Lubricant quantities for grease lubrication – MG series
The lubricant quantities given below are reference values, which may vary depending on the ambient conditions.
If the linear guideways are installed vertically, on the side or with the rail on the top, the relubrication quantities
must be increased by approx. 50 %.
The removal of the existing lubricant is only necessary if the lubricants are not miscible.
8.12 Changing lubricant
Before you change to a different lubricant, the entire block must be thoroughly cleaned. More information on this can be
found in Section 7.1.
8.13 Lubricant quantities
8.13.1 Lubricant quantities for grease lubrication