USER MANUAL
12 13
USER
Uncovering the right-side panel on the BMS reveals mulple
ports and DIP switches necessary for installaon and
communicaons with the inverter. Do not tamper with these
switches or ports aer a successful installaon unless you are
an electrician cered and authorized by HomeGrid, or you are
guided to do so by our internal tech support team.
Stack’d Series BMS - DIP Switches and Connectors
1 9
2 10
3 11
4 12
5 13
6 14
7 15
8 16
Inverter Protocol Selecon
Switch
Parallel Communicaon
Port A
Parallel Communicaon
Port B
Inverter CAN
Communicaon Port
Inverter RS485
Communicaon Port
CAN Upgrade
Communicaon Port
RS232 Communicaon
Interface
Charge/Discharge Negave
Charge/Discharge Posive
Imped. SET
Controller Address Dial
Switch
Dry Contact
Inverter CAN/ RS485
Communicaon Port
Hall Current (Reserved)
Reserved
Reserved
EMSL AN LINK-B LINK-A
INV-CAN INV-485 DBG-COMD BG-232
DRY CONTACT
AUXILIARY POWER
INVERTER COM
ON
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
1
2
3
4
5
6
IMPD SET
ADDR SET
INV SET
2 3 6 5
1 4
11
7
12
8
13
9
14 15 16
10
Stack’d Series BMS - Error Codes Reference Chart
An error code will only be displayed if a fault occurs. If the
system is operang normally the error code will not be shown.
The error codes are shown in the table below:
When the system is charging, the display streamline gathers
in the middle. When it is discharging the display streamline
disperses to both sides.
000
014
002
015
003
016
004
019
005
020
006
022
007
023
008
025
009
051
011
052
053
013
054
Normal
Charge circuit fault
Low voltage protecon
Cell failure
Charging over-current
protecon
Discharge over-current
protecon
Failure
External equipment
communicaon fault
Internal equipment
communicaon fault
Short circuit protecon
Charging high temperatures
Relay over temperature
protecon
Copper bus over temperature
protecon
Lost communicaon between
screen and device
Overcharge protecon
Over discharge protecon
Low ambient temperature
protecon
MOS over temperature
protecon
High discharge temperature
Low charging temperature
Low discharge temperature
High ambient temperature
Discharge circuit failure