Alarms
A gas detected event supersedes anything. When a gas alarm occurs, even when displaying other
behavior, the device goes back to the home screen and displays appropriate gas behavior.
When more than one alarm occurs on one sensor, the highest priority is displayed: Over Range >
High > STEL, TWA, Low, Negative.
When more than one sensor alarms, the alarm status is displayed as multi-alarm no matter what
kind of gas alarms they are.
Alarm type from high
priority to low
Description
Multi-
Alarm
Alarm 2 icon lights red and flash every second. Left and Right
alarm LEDs flash every second. Alarmed sensor LEDs flash twice
every second. Beeps and vibrates.
Over
Range
Alarm 2 icon lights red and flash twice every second. Left and
Right alarm LEDs flash every second. Alarmed sensor LED
flashes twice every second. Beeps and vibrates.
High
Alarm 2 icon lights red and flash once every second. Left and
Right alarm LEDs flash every second. Alarmed sensor LED
flashes twice every second. Beeps and vibrates.
BW Icon 38 User Manual
www.CanarySense.com