To bind the Room Temperature
Sensor (HCW82 or HCF82)
1
Press the bind button on the bottom right hand corner
of the unit once. The red LED light will flash
2
You should receive a SUCCESS message on the
evohome Controller (if not go back and re-bind)
Then, on the Wireless Relay Box (BDR91)
1
Press and hold the button for 15 seconds (until the red
LED blinks rapidly) to clear any previous binding data
2
Press and hold the button again for 5 seconds
(until the red LED blinks slowly)
3
On the evohome Controller press
the green bind button
4
You should receive a SUCCESS message on the
evohome Controller (if not go back and re-bind)
HOLD
15 SEC
HOLD
5 SEC
1 2
1