Binding the HR80 actuator(s)4.3.2
Follow the guided or expert conguration until the f
following screen appears.
Position the f evotouch controller as close as possible
to the HR80 actuator(s).
Consecutively press the bind buttons (1) on all the f
HR80 radiator controllers of the zone.
Press the BIND button on the f evotouch controller to
send the signal.
The symbol
flashes and the software version number
is displayed for 30 seconds.
During the binding procedure, the
symbol is shown
continuously in the display of the HR80 radiator
controller. The display shows:
sync
.
The HR80 radiator controller is receiving data from
the evotouch controller. This process can take up to
4 minutes.
i
The binding procedure mode remains active at the
HR80 radiator controller for a maximum of 4 minutes.
i
NEXT leads you to the RF communication check.