EasyManua.ls Logo

Honeywell Evohome

Honeywell Evohome
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Manual 33
Binding the evotouch controller to the OPENTHERM-Bridge boiler 4.5
feedback
i
The following modules can be used for boiler feedback as well: BDR91, HC60NG, R6660D.
For the BIND buttons and checking RF communication of these modules see section 4.4.
Binding procedure4.5.1
Follow the guided or expert conguration until the f
following screen appears.
Press and hold the bind button (1) of the OPENTHERM- f
Bridge for 5 seconds to activate the bind mode.
Press the BIND button on the the f evotouch controller
to send the bind signal to the OPENTHERM-Bridge.
The red LED of the OPENTHERM-Bridge is switched
off to confirm a successful binding.
i
Binding is terminated automatically after 5 minutes.

Other manuals for Honeywell Evohome