44 evotouch
Deactivating the RF communication check
Remove and re-insert the batteries of the DT92. f
or
Disconnect the power supply. f
or
Press the bind button. f
Completing conguration
Press the DONE button. f
Configuration of the HCW82 / HCF82 is completed.
Binding the evotouch controller to the HB85 temperature sensor4.10
Binding procedure4.10.1
i
To check whether the radio connection is ready for later operation, during binding the temperature sensor module
should remain as near as possible to the mounting site.
Follow the guided or expert conguration until the f
following screen appears.
Press the bind button (1) on the HB85. f
Binding takes place automatically.
i
Binding is terminated automatically after 4 minutes.
i
After successful binding, the HB85 transmits the
measured data to the evotouch controller at intervals
of approx. 10 minutes.