EasyManua.ls Logo

Honeywell HON COCON 13 - Troubleshooting

Honeywell HON COCON 13
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operators manual
© 2017 Honeywell International Inc.
Operators manual underground gas pressure reducing station
Type: HON COCON 13
Page 26
4.5Troubleshooting
Thecartridgemustbereadjustedifitisnotoperatingasrequired.Thecartridge'soperatingobjectivesaredescribed
inparagraph2.4onpage13.Adjustmentdatacanbefoundinparagraph4.4.
Failurescanbecausedby:
Problem1 : Theoutletpressureistoohigh.
Cause1a : The
regulatorpilothasnotbeencorrectlyadjusted.
Solution1a : Readadjustthepilot.Seeparagraph4.4.
Cause1b : Theregulatorhasfailedopen.Thessdvalveisclosed
Solution1b : Replacethecartridgewithasparecartridge.Checkthedefectivecartridgeintheworkshop.
Problem2 :
Theoutletpressureistoolow.
Cause2a : Theregulatorpilothasnotbeencorrectlyadjusted.
Solution2a : Readjustthepilot.Seeparagraph4.7.
Cause2b : Thedifferentialpressurep(p1p2)istoosmall.
Solution2b : Increasetheinletpressure.
Cause2c : Thefilter
isseverelypolluted.
Solution2c : Replacethefilterwithanewone.Seeparagraph4.10.3..
Problem3 : Gasisrequired,butisnotpassingthrough.
Cause3a : Theballvalveisclosed.
Solution3a : Opentheballvalve.
Cause3b : Theoutletvalveis
closed.
Solution3b : Opentheoutletvalve.
Cause3c : Thevalveinthesupplypipe,locatedwithinadistanceof5metersfromthestation'sinlethas
closed.
Solution3c : Openthevalveinthesupplypipe.
Cause3d : Thevalveinthedischargepipe,located
withinadistanceof5metersofthestation'soutlethas
closed.
Solution3d : Openthevalveinthedischargepipe.
Cause3e : Theregulatorpilothasnotbeencorrectlyadjusted.
Solution3e : Readjustthepilot.Seeparagraph4.7.
Cause3f : Thessdvalvehasclosed.
Solution3f : Replacethecartridgewithasparecartridge.Checkthedefectcartridgeintheworkshop.
Problem5 : Thereiswateronthecartridge.
Cause5 : Thecartridgeandthepitcoversealsareworn.
Solution5 : Replacethesealrings.
Problem6 : Thereisdust
inthedischargepipe.
Cause6 : Thefilterisdefect.
Solution6 :Replacethedefectfilterwithanewfilter.Seeparagraph4.8.3..