INTELLIGUARD 9000™
25 74-3047—1
HOLD-UP TEST EVENT LOG
The HOLD-UP TEST Event Lo
shows the followin
:
NOTE: Each time the same actuator’s buttons are s
ueezed
durin
a test se
uence, an entr
is made in the
Event Lo
. Therefore, one BIC-2 HU point ma
appear more than once in the Event Lo
for that test
se
uence.
— Point restoral for all of the Hold-up actuators depressed
durin
the test
text shown in lower case letters
.
— End of test
text shown in capital letters
.
— Alarms of all of the Hold-up actuators depressed durin
the
test
text shown in capital letters
.
— Start of test
text shown in capital letters
.
2. Enable/Disable CHIME Function
NOTES:
— The CHIME function is onl
functional when the
Chime enabled areas are disarmed. No results
are lo
ed.
— The LED located below the CC2 displa
blinks
when the Chime is activated. Therefore, the CC2
provides both audible and visual notification of an
event, whereas the KID notification is onl
audi-
ble.
1.
From the Test menu, select the
2-CHIME
menu.
2.
Press the
ACCEPT
ke
. The CC2 displa
re
uests an
area number.
3.
Enter an area number
can be an
area from 1 to 8, but
must be an active area
. The displa
s shows either
CHIME: ENABLED
or
CHIME: DISABLED
.
4.
To chan
e the settin
, press the
ACCEPT
ke
and then
press the scroll down ke
one stroke at a time until the
re
uired settin
is displa
ed.
5.
Press the
ACCEPT
ke
and the s
stem returns to the
2-
CHIME
menu.
6.
Press the scroll ke
s or numbers 1, 3 or 4 to move to a
different test menu, return to step 2 to chan
e the set-
tin
s for other areas, or to
o to the next step.
NOTE: When the settin
s are made, the
remain valid until
chan
ed
even if
ou have exited the test menus
.
7.
Open and close the door
s
associated with the
selected area to verif
that the CHIME function works
properl
. The CC2 beeps twice and the LED blinks each
time a door
defined as point t
pe 1
is opened.
The
beep is heard on an
CC2 or KID assi
ned to the test
area
.
8.
From the CC2, press the
X
ke
to exit to the main menu,
Intelliguard 9000
, or press a menu ke
.
The followin
example explains how the CHIME func-
tion works:
— A s
stem has areas 1, 2, 3, 4 and 5 active.
— The CHIME function is enabled for areas 2 and 4.
— Point 2 is pro
rammed as door 2 and point 4 is
pro
rammed as door 4
both as t
pe 1
.
— Area 2 is armed and area 4 is disarmed.
— When doors 2 and 4 are opened, onl
door 4 acti-
vates a chime on the CC2 and/or KID assi
ned to
area 4.
— No chime is heard on the CC2 and/or KID
assi
ned to area 2 even thou
h door 2 was
opened because area 2 is still armed.
— Disarm area 2.
— When a CC2 or KID is assi
ned to multiple areas,
such as areas 1, 2 and 4, the chime sounds when
those area doors are opened.
3. WALK-TEST Procedure
1.
Check to see if an
points are in alarm.
2.
Make an
necessar
corrections.
NOTE: All points tested must transition from normal to alarm
and return to normal to be re
istered in the Event
Lo
.
3.
From the CC2, press the
MODE
ke
.
4.
Enter
our technician ID and code number
00, 9999
.
5.
Enter
4
on the CC2 to clear the Event Lo
and then
press the
ACCEPT
ke
.
6.
Press the
TEST
ke
.
7.
Press
3
to select
WALK-TEST
.
8.
Press the
ACCEPT
ke
.
9.
Enter the test area number.
WALK-TEST
is displa
ed
on the CC2.
10.
Walk throu
h the selected area of the buildin
selected
in previous step
and test each alarm input on each
device except the Hold-up actuators. As each point is
tested and
oes into alarm, all CC2s assi
ned to this
area beep and their LEDs blink to indicate that the
alarms have been received b
the I9000.
11.
Restore each alarm input in the area.
If red Hold-up
actuators are tested, a manual
Reset Detectors
com-
mand must be made. BIC-2 HU inputs, other than the
red Hold-up actuator, should be tested with the
WALK-
TEST
.
NOTE: Actuators defined as Hold-up are not shown as
tested oka
in the Event Lo
when usin
the
WALK
-
TEST
, therefore, it is recommended that the HOLD-
UP TEST procedure be used.
12.
From the CC2, press the
X
ke
to end the test. The
I9000 s
stem automaticall
performs a communication
test
COM Test
for each device that is associated with
the specified area
specified in step 9
.
NOTE: When a user ID/pass code other than the techni-
cian’s is used, the communication tests
COM Test
are not done and the result is not included in the lo
.
13.
Press the
MODE
ke
.
14.
Press
3
to select
EVENT LOG
.
15.
Press the
ACCEPT
ke
to view the Event Lo
.
16.
View the results of the test in the Event Lo
. See the
Walk Test Event Lo
section for an example of the Lo
results.
NOTE: When a user ID/pass code other than the techni-
cian’s is used, the communication tests
COM Test
are not done and the result is not included in the lo
.
17.
Repeat steps 5 throu
h 16 for each of the pro
rammed
areas at the installed site.