Lyric Controller Programming Guide
Program Zones (Continued)
Programming Field
Function and Action
Supervision
Select supervision for device being enrolled. The system displays the applicable
options based upon the Device Type that was selected. Select “Supervision” to scroll
between the following options:
Options:
Hardwire Zone
Normal Open
Normal Closed
End of Line
RF Zone
Supervised
Unsupervised
Temperature
High Temp (Default selection for Zones 280, 282, 284 and 286, 288, 290)
Low Temp (Default selection for Zones 281, 283, 285 and 287, 289, 291)
Select “Save” if programming is complete. The system returns to the Zone
Programming screen.
Arm Night
Allows specific programmed motion sensors to be active when Arm Night Stay mode
is enabled and the system is Armed in Stay mode by the User. If “Motion Sensor” is
selected in the Response Type Field, the Arm Night option will be available.
Options:
Yes
No
Select “Save” if programming is complete. The system returns to the Zone
Programming screen.
After all Zones have been enrolled, the SiX™ Series Device firmware should be updated to ensure
the latest version is being used. Refer to the Updating SiX™ Series Sensor and Key Fob firmware
section.
Batch Learning Enrollment (SiX™ Series Devices only)
The Lyric Controller is capable of learning multiple SiX Series devices via the Batch (RF) Learning Mode. The
system will assign each wireless device enrolled via the Batch Learning mode to the next available zone.
Programming Field
Function and Action
Zones
After entering the Zone Programming mode, select RF6 Batch “Start” to enter batch
learning mode. Fault and restore each of the sensors being enrolled. When batch
learning is complete select RF6 Batch Stop”. (Refer to the documentation provided
with the specific SiX™ device being enrolled for additional information.)
The controller will assign the device to the next available Zone. The device’s battery
level and signal strength is displayed on the Lyric control.
NOTE:
The default “Service” for the SiXCT Contacts is set to “Reed” whether learned
locally at the Controller or via TotalConnect 360.
To change the Service to “Contact” perform the following for each applicable Zone:
1. Select the appropriate Zone and then select Edit”
2. Select “Service”. The system toggles between “Reed” and “Contact”.
3. Select “Save”.
4. Select the “” key to exit the current screen. The system returns to the previous
screen.
NOTE:
Re-entering Batch Programming mode after exiting from Zone Programming, will
require exiting and re-entering Installer Programming,
- 15 -