36-KI-16-33
Page 2 of 4
Availability
MGG19D
TABLE I (continued)
D - Electrodes
SUS316L _ _ _ _ _ _ L _ _ _ _ _
Hastelloy C
(with Teflon PFA only) _ _ _ _ _ _ C _ _ _ _ _ c
Titanium _ _ _ _ _ _ K _ _ _ _ _
Zirconium
(with Teflon PFA only) _ _ _ _ _ _ H _ _ _ _ _ c
Tantalum (with Teflon PFA only) _ _ _ _ _ _ T _ _ _ _ _ c
Tungsten Carbide _ _ _ _ _ _ W _ _ _ _ _
Platinum-Iridium
(with Teflon PFA only) _ _ _ _ _ _ P _ _ _ _ _ c
Alloy 20 (with Teflon PFA only) _ _ _ _ _ _ A _ _ _ _ _ c
Hastelloy B (with Teflon PFA only) _ _ _ _ _ _ B _ _ _ _ _ c
SUS304 (with Teflon PFA only) _ _ _ _ _ _ E _ _ _ _ _ c
Monel (with Teflon PFA only) _ _ _ _ _ _ M _ _ _ _ _ c
Nickel (with Teflon PFA only) _ _ _ _ _ _ N _ _ _ _ _ c
SUS316L Protruded Tip (with Teflon PFA only) _ _ _ _ _ _ 1 _ _ _ _ _ c
SUS316L for Alumina with Flat Tip (with Teflon PFA only) _ _ _ _ _ _ 2 _ _ _ _ _ c
SUS316L for Alumina with Pointed Tip (with Teflon PFA only)
_ _ _ _ _ _ 3 _ _ _ _ _
c
E - Grounding Rings
SUS316 _ _ _ _ _ _ _ S _ _ _ _
SS Top Hat Style (Upstream Only) _ _ _ _ _ _ _ G _ _ _ _
c
Hastelloy C (with Teflon PFA only) _ _ _ _ _ _ _ C _ _ _ _ c
Titanium _ _ _ _ _ _ _ K _ _ _ _
Zirconium
(with Teflon PFA only) _ _ _ _ _ _ _ H _ _ _ _ c
Tantalum (with Teflon PFA only) _ _ _ _ _ _ _ T _ _ _ _ c
Platinum (with Teflon PFA only) _ _ _ _ _ _ _ P _ _ _ _ c
Alloy 20 (with Teflon PFA only) _ _ _ _ _ _ _ A _ _ _ _ c
Hastelloy B (with Teflon PFA only) _ _ _ _ _ _ _ B _ _ _ _ c
SUS304 (with Teflon PFA only) _ _ _ _ _ _ _ E _ _ _ _ c
SUS316L (with Teflon PFA only) _ _ _ _ _ _ _ L _ _ _ _ c
Nickel (with Teflon PFA only)
_ _ _ _ _ _ _ N _ _ _ _
c
F - Wiring Connection/Water Tight Gland
G1/2 Internal Thread with Brass (Ni-plated) Water Tight Gland
_ _ _ _ _ _ _ _ 3 _ _ _
G1/2 Internal Thread with SUS304 Water Tight Gland
_ _ _ _ _ _ _ _ 8 _ _ _
G - Face to Face Dimension
Standard _ _ _ _ _ _ _ _ _ A _ _
Competitive Refer to Table 103 and Consult Factory)
_ _ _ _ _ _ _ _ _ 9 _ _
c
H - Installation/Wiring Direction - Remote Only
Upstream Side
(horizontal/vertical piping mounting) _ _ _ _ _ _ _ _ _ _ A _
Downstream Side (horizontal/vertical piping mounting) _ _ _ _ _ _ _ _ _ _ B _
Horizontal Piping Mounting/Left Side Viewed from Upstream _ _ _ _ _ _ _ _ _ _ C _
Horizontal Piping Mounting/Right Side Viewed from Upstream
_ _ _ _ _ _ _ _ _ _ D _
I - Calibration
Standard Calibration - 2 Point (0, 100%) w/ Master Converter _ _ _ _ _ _ _ _ _ _ _ R
3 Point (0, 50, 100%) with Master Converter _ _ _ _ _ _ _ _ _ _ _ P
5 Point (0, 25, 50, 75, 100%) with Master Converter _ _ _ _ _ _ _ _ _ _ _ Q
2 Point (0, 100%) with Customer’s Specific Converter _ _ _ _ _ _ _ _ _ _ _ J
3 Point (0, 50, 100%) with Customer’s Specific Converter _ _ _ _ _ _ _ _ _ _ _ A
5 Point (0, 25, 50, 75, 100%) with Customer’s Specific Converter
_ _ _ _ _ _ _ _ _ _ _ E