PRIMUSr 1000 Integrated Avionics System
A28--1146--112--00
5-19
Engine Instrument and Crew Alerting System (EICAS)
Color Percentage of RPM
Amber < 95
Green 96 -- 104
Amber 104 -- 110
Red 111 <
APU Turbine Speed as a Percentage of RPM
Table 5--15
Color Percentage of RPM
Green < 680 °C
Amber 681° C -- 717° C
Red 718° C <
APU Exhaust Temperature
Table 5--16